neumann.berlin
the microphone company
The calibration microphone features a linear frequency
range of 20-16,000 Hz, with a maximum deviation of
+/- 1 dB. Neumann used the calibration microphone in
conjunction with two Neumann P2 level recorders for qual-
ity control of its own microphone production. The combi-
nation of the calibration microphone with one level record-
er served to maintain a
constant sound pressure
level in the calibration
room, independent of the
frequency. The second lev-
Calibration Microphones
MM 2, MM 3, MM 5
As an audio pioneer, Neumann
is constantly charting new terri-
tory. In the early years, when
microphone production was still
in its infancy, new problems
were encountered at nearly eve-
ry turn. For example, how can a
thin diaphragm be produced
from plastic? Neumann solved
this particular problem by heat-
ing the plastic and pouring a con-
trolled amount onto the surface
of water.
el recorder monitored the
output voltage of the mi-
crophone under investiga-
tion.
The MM 2 was succeeded
in 1954 by the MM 3,
which had the same speci-
fications, but was equipped
with the AC 701(k) tube
in place of the VF 14 M.
For the very first microphone
amplifiers, resistors were fash-
ioned from thin bars of graphite.
Acoustic measuring devices
hardly existed. So Neumann de-
veloped the first practical loga-
rithmic level recorder. For the
absolute calibration of pressure
microphones, Neumann de-
signed a pistonphone. In the best
pioneering tradition, Neumann
used these devices as indispen-
sable tools and aids for explor-
ing the frontiers of acoustic re-
search and the realization of in-
novative ideas.
For detecting higher fre-
quencies up to 50 kHz –
for example, when testing
acoustic models in reduced scale – Neumann developed
an even smaller capsule with a Nickel diaphragm, known
as the MM 5. Introduced in 1955, the MM 5’s frequency
response up to 20 kHz is as consistent as that of the MM 2
and MM 3. In the 20 kHz
to 50 kHz range, the tol-
erance is less than 3 dB.
These close tolerances
were regularly checked in
cooperation with the Nat-
ural Metrology Institute in
Braunschweig, (now Phy-
sikalisch Technische Bun-
desanstalt, the German
equivalent of National Bu-
reau of Standards).
The industry also lacked a cali-
bration standard for the acous-
tic testing of microphones. In
1949 Neumann developed a
miniature microphone capsule
that functioned as a pressure
transducer. The aluminum mem-
brane measures 10 mm in diam-
eter. To prevent disturbing the
sound field in the calibration
room by the relatively large mi-
crophone amplifier, the capsule
assembly is separated from the
amplifier housing with electri-
cal connection running through
a thin tube of 25 cm length. The
amplifier is modified from the
electronics used in the U 47,
with the same tube model
VF 14 M.
Just as Neumann level
recorders were standard
equipment in most acous-
tic calibration laboratories
of the time, Neumann
calibration microphones
served for decades as the
standard for nearly all
manufacturers of microphones and loudspeakers. Calibra-
tion microphones continued to be produced until the ear-
ly 1970s. Today, almost thirty years later, many of them
are still in service.
|
NEC Portable Media Storage IS016 5E User Manual
NETGEAR Network Card WNDAP330 100NAS User Manual
NeumannBerlin Electric Pressure Cooker D1761 User Manual
NordicTrack Home Gym NTC40150 User Manual
NotaTech Switch 8000SeriesI O User Manual
Opticon Scanner LPN5627 User Manual
Panasonic Air Conditioner CS C12CKP User Manual
Panasonic All in One Printer KX PW708DLE5 User Manual
Panasonic DVD Player DVD S27 User Manual
Parkside Saw PHKS 1300 A1 User Manual